FASTData January 1999 Release| Descriptions | |
| FDMS: | Obtaining Data |
| Documentation Abstract: |
Computer-Aided Molecular Design of Fire Resistant Aircraft Materials. |
| Material: | Polyvinyl Alcohol (Liquid) |
| Lab: | National Institute of Standards and Technology |
| Sponsor: | National Institute of Standards and Technology |
| Date: | 9/24/1993 |
| Test Ref No: | T6050 |
| Tested by: | Jack Lee |
| Approved by Scientific Officer: | James Brown |
| Mass Lost: | 5818.93 g/m2 | Total Heat Released: | 103.415 MJ/m2 |
| Peak RHR: | 193.96 kW/m2 | Peak Mass Loss Rate: | 14.5638 g/m2s |
| Units | Test Mean | 60 s | 180 s | 300 s | |
| Heat Release | kW/m2 | 146.903 | 182.808 | 159.034 | 161.588 |
| Mass Loss Rate | g/m2s | 0.00891943 | 0.0133889 | 0.0113507 | 0.0106727 |
| Heat of Combustion | MJ/kg | 17772100 | 13.6536 | 14.011 | 15.1404 |
| Specific Ext. Area | m2/kg | - | - | - | - |
| Carbon Dioxide | kg/kg | 1.54472 | 1.22552 | 1.24612 | 1.33911 |
| Carbon Monoxide | kg/kg | 0.0231419 | 0.00326992 | 0.00780331 | 0.00959904 |
Flaming out time 12 min 55 second/774 second. Sample smokes
34 second, blister at edge/spread to center 52 second, flame
at outer edges 2 minute,edges of sample puffed up in cone
2 min. 50 second. TUH/H20 analyzers are down-no soot collect
spark ignited used with foam glass-sample in al. foil pan
| Heat Flux: | 40 kW/m2 | Nominal Flow: | 24 l/s |
| Orifice Constant: | 0.0434273 | Heat per Unit Mass O2: | 13.1 J/kg |
| Heater Orientation: | H | Spark Ignitor Used: | Y |
| Grid Used: | N | Frame Used: | N |
| Conditioning: | 50 RH @ 296 K | Test Conditions: | 50 RH |
| Specimen Thickness: | - | Specimen Area: | 0.00467 m2 |
| Initial Mass: | 0.0305 g | Time of Peak RHR: | 105 s |
| Final Mass: | 0.00332558 g | Peak RHR: | 193.96 kW/m2 |
| Mass Lost: | 5818.93 g/m2 | Peak Mass Loss Rate: | 14.5638 g/m2s |
| Ignition Time: | 64 s | Peak Extinction Area: | - |
| Flameout Time: | 774 s | Total Heat Released: | 103.415 MJ/m2 |
| Publication Status: | Unpublished |
| Statistical Basis of Data: | Replicate data available for the same test method and test conditions |
| Material Development/ Production Status: | Experimental material |
| Evaluation Status: | Data have been validated |
| Laboratory Accreditation Status: | The laboratory is recognized by (inter)national accreditation bodies |
| Completeness of Material Description: | Partial information on material |
| Completeness of Test Procedure Description: | Standard test procedure |