FASTData January 1999 Release| Descriptions | |
| FDMS: | Obtaining Data |
| Documentation Abstract: |
Computer-Aided Molecular Design of Fire Resistant Aircraft Materials. |
| Material: | Polyvinyl Alcohol (Liquid) |
| Lab: | National Institute of Standards and Technology |
| Sponsor: | National Institute of Standards and Technology |
| Date: | 9/21/1993 |
| Test Ref No: | T6045 |
| Tested by: | Jack Lee |
| Approved by Scientific Officer: | James Brown |
| Mass Lost: | 4141.36 g/m2 | Total Heat Released: | 59.5096 MJ/m2 |
| Peak RHR: | 154.669 kW/m2 | Peak Mass Loss Rate: | 10.5077 g/m2s |
| Units | Test Mean | 60 s | 180 s | 300 s | |
| Heat Release | kW/m2 | 114.558 | 132.851 | 120.981 | 126.899 |
| Mass Loss Rate | g/m2s | 0.0072792 | 0.00943221 | 0.00801056 | 0.00791759 |
| Heat of Combustion | MJ/kg | 14369600 | 14.0848 | 15.1026 | 16.0274 |
| Specific Ext. Area | m2/kg | - | - | - | - |
| Carbon Dioxide | kg/kg | 1.37032 | 1.30276 | 1.44699 | 1.52928 |
| Carbon Monoxide | kg/kg | 0.0115541 | 0.00773407 | 0.0065758 | 0.00817437 |
Flaming out time 11 minute 14 second/678 seconds. Sample
blistered 79 seconds and smokes 2 minutes. Sample flames at
edges 5 minutes 34 seconds and delaminates up.
| Heat Flux: | 20 kW/m2 | Nominal Flow: | 24 l/s |
| Orifice Constant: | 0.0428552 | Heat per Unit Mass O2: | 13.1 J/kg |
| Heater Orientation: | H | Spark Ignitor Used: | Y |
| Grid Used: | N | Frame Used: | N |
| Conditioning: | 50 RH @ 296 K | Test Conditions: | 50 RH |
| Specimen Thickness: | - | Specimen Area: | 0.004418 m2 |
| Initial Mass: | 0.02726 g | Time of Peak RHR: | 155 s |
| Final Mass: | 0.00896348 g | Peak RHR: | 154.669 kW/m2 |
| Mass Lost: | 4141.36 g/m2 | Peak Mass Loss Rate: | 10.5077 g/m2s |
| Ignition Time: | 153 s | Peak Extinction Area: | - |
| Flameout Time: | 678 s | Total Heat Released: | 59.5096 MJ/m2 |
| Publication Status: | Unpublished |
| Statistical Basis of Data: | Replicate data available for the same test method and test conditions |
| Material Development/ Production Status: | Experimental material |
| Evaluation Status: | Data have been validated |
| Laboratory Accreditation Status: | The laboratory is recognized by (inter)national accreditation bodies |
| Completeness of Material Description: | Partial information on material |
| Completeness of Test Procedure Description: | Standard test procedure |