FASTData January 1999 Release

Test Type: Cone Calorimeter, Test Number: T5633, Description File: t5633



Descriptions
FDMS: Obtaining Data
Documentation
Abstract:
Computer-Aided Molecular Design of Fire Resistant Aircraft Materials.
Material:Polystyrene Disk (7.3cm diameter)
Lab:National Institute of Standards and Technology
Sponsor:National Institute of Standards and Technology
Date:10/26/1992
Test Ref No:T5633
Tested by:Jack Lee
Approved by
Scientific Officer:
James Brown

Test Results (summary)

Mass Lost:3075.25 g/m2 Total Heat Released:89.4236 MJ/m2
Peak RHR:471.634 kW/m2Peak Mass Loss Rate:16.7494 g/m2s

Summary Data From Ignition

Units Test Mean 60 s 180 s 300 s
Heat Release kW/m2 275.199 203.643 327.266 295.968
Mass Loss Rate g/m2s 0.0122517 0.00605756 0.0110171 0.00988809
Heat of CombustionMJ/kg28669000 31.9608 29.0329 29.8202
Specific Ext. Aream2/kg - - - -
Carbon Dioxidekg/kg 1.92613 2.40856 2.28206 2.07172
Carbon Monoxidekg/kg 0.0553413 0.0456344 0.0522056 0.0606616

Observations and Comments

Flaming out time 8 minutes
Sample started to smoke at 50 seconds
Sample started to flashing at 125 seconds
No soot collected-TUH is down-Spark ignited used

Details of Test Procedure Used

Heat Flux: 40 kW/m2 Nominal Flow:24 l/s
Orifice Constant: 0.0393211 Heat per Unit Mass O2:12.98 J/kg
Heater Orientation:H Spark Ignitor Used:Y
Grid Used: N Frame Used:N
Conditioning: 50 RH @ 296 K Test Conditions: 50 RH
Specimen Thickness:- Specimen Area:0.0043 m2

Test Results

Initial Mass: 0.0127 g Time of Peak RHR: 330 s
Final Mass: - Peak RHR: 471.634 kW/m2
Mass Lost: 3075.25 g/m2 Peak Mass Loss Rate: 16.7494 g/m2s
Ignition Time:151 s Peak Extinction Area:-
Flameout Time:483 s Total Heat Released: 89.4236 MJ/m2

Test Quality Indicators

Publication Status:Unpublished
Statistical Basis of Data:Data available for the same test method, but different test conditions
Material Development/
Production Status:
Experimental material
Evaluation Status:Data have been validated
Laboratory
Accreditation Status:
The laboratory is recognized by (inter)national accreditation bodies
Completeness of
Material Description:
Partial information on material
Completeness of Test
Procedure Description:
Standard test procedure

Test Results (summary)

Data Plots

Heat release rate per unit area

Mass Loss Rate Per Unit Area

CO2 Yield

CO Yield

Smoke Extinction Area