FASTData January 1999 Release

Test Type: Cone Calorimeter, Test Number: T5628, Description File: t5628



Descriptions
FDMS: Obtaining Data
Documentation
Abstract:
Computer-Aided Molecular Design of Fire Resistant Aircraft Materials.
Material:Polystyrene Disk (7.3cm diameter)
Lab:National Institute of Standards and Technology
Sponsor:National Institute of Standards and Technology
Date:10/24/1992
Test Ref No:T5628
Tested by:Jack Lee
Approved by
Scientific Officer:
James Brown

Test Results (summary)

Mass Lost:2796.91 g/m2 Total Heat Released:87.2671 MJ/m2
Peak RHR:228.724 kW/m2Peak Mass Loss Rate:7.43338 g/m2s

Summary Data From Ignition

Units Test Mean 60 s 180 s 300 s
Heat Release kW/m2 166.265 189.402 190.761 200.984
Mass Loss Rate g/m2s 0.00585042 0.00537597 0.00574984 0.00622299
Heat of CombustionMJ/kg30425400 34.0255 32.794 32.1098
Specific Ext. Aream2/kg - - - -
Carbon Dioxidekg/kg 2.30515 2.84046 2.63291 2.53368
Carbon Monoxidekg/kg 0.0519943 0.0483758 0.0532231 0.0571609

Observations and Comments

Flaming out time at 19 minutes and 9 seconds
Change ignition time to 10 minutes and 20 seconds(620 sec.)
Sample started to smoke at 4 minutes and 10 seconds
Sample flashed at 7:24 and between 10:00.
Spark ignited used-NO soot-TUH is down-47mm from top of cone

Details of Test Procedure Used

Heat Flux: 20 kW/m2 Nominal Flow:24 l/s
Orifice Constant: 0.0391792 Heat per Unit Mass O2:12.98 J/kg
Heater Orientation:H Spark Ignitor Used:Y
Grid Used: N Frame Used:N
Conditioning: 50 RH @ 296 K Test Conditions: 50 RH
Specimen Thickness:- Specimen Area:0.0043 m2

Test Results

Initial Mass: 0.0119 g Time of Peak RHR: 840 s
Final Mass: - Peak RHR: 228.724 kW/m2
Mass Lost: 2796.91 g/m2 Peak Mass Loss Rate: 7.43338 g/m2s
Ignition Time:620 s Peak Extinction Area:-
Flameout Time:1148 s Total Heat Released: 87.2671 MJ/m2

Test Quality Indicators

Publication Status:Unpublished
Statistical Basis of Data:Data available for the same test method, but different test conditions
Material Development/
Production Status:
Experimental material
Evaluation Status:Data have been validated
Laboratory
Accreditation Status:
The laboratory is recognized by (inter)national accreditation bodies
Completeness of
Material Description:
Partial information on material
Completeness of Test
Procedure Description:
Standard test procedure

Test Results (summary)

Data Plots

Heat release rate per unit area

Mass Loss Rate Per Unit Area

CO2 Yield

CO Yield

Smoke Extinction Area


FASTData Home