Fire Publications - calorimeters
calorimeters
- Analysis of Large-Scale Fire Test Data.
Fire Safety Journal, Vol. 17, No. 5, 387-414, 1991.
Peacock, R. D.; Babrauskas, V.
- Calculations of the Heat Release Rate by Oxygen Consumption for Various Applications.
NBSIR 81-2427-1; 41 p. March 1982.Journal of Fire Sciences, Vol. 2, No. 5, 380-395, September/October 1984.
Parker, W. J.
- Calibration Technique for Heat Flux Sensors Used in Fire Experiments and Standard Fire Tests.
NIST SP 971; DOT/FAA/CT-89/26; 32 p. August 2001.NIST SP 971: "Collected Reports and Publications by the National Institute of Standards and Technology on Heat Flux Gage Calibration and Usage.", 2001.
Steckler, K. D.; Tu, K. M.; Twilley, W. H.
- Evaluation of the Effectiveness of Fire Resistant Durable Agents on Residential Siding Using an ICAL-Based Testing Protocol.
Fire and Materials 2001. 7th International Conference and Exhibition. Proceedings. Interscience Communications Limited. January 22-24, 2001, San Antonio, TX, 241-248 pp, 2001.
Grand, A. F.; Mehrafza, M.
- Fire Performance of Furnishings as Measured in the NBS Furniture Calorimeter. Part 1.
NBSIR 83-2787; 133 p. January 1984.
Lawson, J. R.; Walton, W. D.; Twilley, W. H.
- Fire Tests of Amtrak Passenger Rail Vehicle Interiors. Final Report. 1978-1983.
NBS TN 1193; 115 p. May 1984.
Peacock, R. D.; Braun, E.
- Flammability Hazard of Materials.
Volume 1; Chapter 3 - Section 2; NFPA FPH2008;Fire Protection Handbook, 20th Edition. Volume 1. Chapter 3. Section 2, National Fire Protection Assoc., Quincy, MA, Cote, A. E.; Grant, C. C.; Hall, J. R., Jr.; Solomon, R. E., Editor(s), 2/31-48 p., 2008.
Madrzykowski, D.; Stroup, D. W.
- From Bunsen Burner to Heat Release Rate Calorimeter.
Chapter 2;Heat Release in Fires, Elsevier Applied Science, NY, Babrauskas, V.; Grayson, S. J., Editor(s)(s), 7-29 pp, 1992.
Babrauskas, V.
- Heat Release Rate (HRR).
NISTIR 6527; 270 p. June 2000.Measurement Needs for Fire Safety: Proceedings of an International Workshop. National Institute of Standards and Technology. April 4-6, 2000, Gaithersburg, MD, Ohlemiller, T. J.; Johnsson, E. L.; Gann, R. G., Editor(s)(s), 186-206 pp, 2000.
Janssens, M. L.
- Investigation of the Effectiveness of Fire Resistant Durable Agents on Residential Siding Using an ICAL-Based Testing Protocol.
NIST GCR 00-792; 152 p. May 2000.
Grand, A. F.
- Microscale Combustion Calorimeter for Determining Flammability Parameters of Materials.
NISTIR 5904; October 1996.National Institute of Standards and Technology. Annual Conference on Fire Research: Book of Abstracts. October 28-31, 1996, Gaithersburg, MD, 89-90 pp, 1996.
Lyon, R. E.; Walters, R. N.
- Modeling the Heat Release Rate of Aircraft Cabin Panels. Final Report.
DOT/FAA/CT-92/3; ACD-240; 52 p. February 1993.
Parker, W. J.; Filipczak, R.
- NIST 3 Megawatt Quantitative Heat Release Rate Facility: Description and Procedures.
NISTIR 7052; 130 p. September 2004.
Bryant, R. A.; Ohlemiller, T. J.; Johnsson, E. L.; Hamins, A.; Grove, B. S.; Guthrie, W. F.; Maranghides, A.; Mulholland, G. W.
- Report on a Study to Utilize the ICAL Apparatus for the Determination of the Effectiveness of Fire Resistant Durable Agents.
NIST GCR 99-774; OPL Project Number 15933-103926; 59 p. May 1999.
Grand, A. F.
- Some Factors Affecting the Design of a Furniture Calorimeter Hood and Exhaust.
NISTIR 5298; 25 p. December 1993.Journal of Fire Protection Engineering, Vol. 6, No. 3, 99-112, 1994.
Cooper, L. Y.
- Some Factors Affecting the Design of a Furniture Calorimeter Hood and Exhaust.
NISTIR 5298; 25 p. December 1993.Journal of Fire Protection Engineering, Vol. 6, No. 3, 99-112, 1994.
Cooper, L. Y.
- Thermal Performance of Fire Resistive Materials. Part 2. A Multi-Layer One-Dimensional Heat Transfer Model for Fire Resistive Materials Protecting a Substrate.
NISTIR 7482; 25 p. February 2008.
Prasad, K. R.; Bentz, D. P.
- Upholstered Furniture Room Fires--Measurements, Comparison with Furniture Calorimeter Data, and Flashover Predictions.
Journal of Fire Sciences, Vol. 2, No. 1, 5-19, January/February 1984.
Babrauskas, V.
- Use of Calorimetry for Fire Materials Research.
DOT/FAA/CT-95/46; AAR-423;National Institute of Standards and Technology. Fire Calorimetry. Proceedings. July 27-28, 1995, Gaithersburg, MD, Hirschler, M. M.; Lyon, R. E., Editor(s)(s), 48-49 pp, 1995.
Kashiwagi, T.
Building and Fire Research Laboratory
National Institute of Standards and Technology
Gaithersburg, MD 20899