Fire Publications - cables
cables
- Assessing the Accuracy of a Physical Fire Model for Obtaining Smoke Toxic Potency Data.
Volume 2;Interflam 2007. (Interflam '07). International Interflam Conference, 11th Proceedings. Volume 2. September 3-5, 2007, London, England, 1021-1032 pp, 2007.
Gann, R. G.; Averill, J. D.; Marsh, N. D.; Nyden, M. R.
- Cable Response to Live Fire (CAROLFIRE) Volume 3: Thermally-Induced Electrical Failure (THIEF) Model.
NISTIR 7472; NUREG/CR-6931; Volume 3; 74 p. April 2008.
McGrattan, K. B.; Dreisbach, J.
- Challenges in Use of State-of-the-Art Fire Modeling Tools in Nuclear Power Plant Applications.
NISTIR 6986; 569 p. September 2003.International Collaborative Project to Evaluate Fire Models for Nuclear Power Plant Applications: Summary of 5th Meeting. APPENDIX D. View Graphs Used for Presentations: Future Tasks and Benchmark Exercises. May 2-3, 2002, Gaithersburg, MD, D/313-324 pp, 2003.
Najafi, B.; Joglar, F.; Kassawara, R.
- Development of a Fire Detection System Using FT-IR Spectroscopy and Artificial Neural Networks.
Fire Safety Science. Proceedings. Sixth (6th) International Symposium. International Association for Fire Safety Science (IAFSS). July 5-9, 1999, Poitiers, France, Intl. Assoc. for Fire Safety Science, Boston, MA, Curtat, M., Editor(s), 791-802 pp, 2000.
Chen, Y.; Serio, M. A.; Sathyamoorthy, S.
- Effectiveness of Condensed Aerosols for Fire Suppression in Electrical Equipment.
HOTWC 2006;Halon Options Technical Working Conference, 16th Proceedings. HOTWC 2006. May 16-18, 2006, Albuquerque, NM, 1-12 pp, 2006.
Agafonov, V. V.; Kopylov, N. P.; Kopylov, S. N.
- EPRI Guide to Fire Modeling: An Overview.
NISTIR 6986; 569 p. September 2003.International Collaborative Project to Evaluate Fire Models for Nuclear Power Plant Applications: Summary of 5th Meeting. APPENDIX D. Regulatory Applications of Fire Models. May 2-3, 2002, Gaithersburg, MD, D/51-68 pp, 2003.
Najafi, B.; Joglar, F.; Kassawara, R.
- Fire Performance of Wire and Cable: Reaction-to-Fire Tests--A Critical Review of the Existing Methods and of New Concepts.
NIST TN 1291; 130 p. December 1991.
Babrauskas, V.; Peacock, R. D.; Braun, E.; Bukowski, R. W.; Jones, W. W.
- Fire Risk Assessment for Telecommunications Central Offices.
Fire Technology, Vol. 34, No. 2, 156-176, May/June 1998.
Parks, L. L.; Kushler, B. D.; Serapiglia, M. J.; McKenna, L. A., Jr.; Budnick, E. K.; Watts, J. M., Jr.
- Foreseen German Real Scale Cable Fire and Functional Failure Tests.
NISTIR 6986; 569 p. September 2003.International Collaborative Project to Evaluate Fire Models for Nuclear Power Plant Applications: Summary of 5th Meeting. APPENDIX D. View Graphs Used for Presentations: Future Tasks and Benchmark Exercises. May 2-3, 2002, Gaithersburg, MD, D/303-306 pp, 2003.
Roewekamp, M.; Riese, O.; Hosser, D.
- Measurement of Thermal Decomposition Products of HFC-227ea in an Electronic Facility.
Halon Options Technical Working Conference. Proceedings. HOTWC 2001. Sponsored by: University of New Mexico, Fire Suppression Systems Assoc., Fire and Safety Group, GlobeTech, Inc., Halon Alternative Research Corp., Hughes Associates, Inc., Kidde plc., Modular Protection, Corp., Next Generation Fire Suppression Technology Program, Sandia National Laboratories, Summit Environmental Corp., Inc. and 3M Specialty Materials. April 24-26, 2001, Albuquerque, NM, Daniels, B. L.; Cole, D. G., Editor(s)(s), 314-320 pp, 2001.
Kim, A. K.; Su, J. Z.; Crampton, G. P.; Kanabus-Kaminska, M.
- Methodology for Developing and Implementing Alternative Temperature-Time Curves for Testing the Fire Resistance of Barriers for Nuclear Power Plant Applications.
NISTIR 5842; 116 p. May 1996.
Cooper, L. Y.; Steckler, K. D.
- Report of Experimental Results for the International Fire Model Benchmarking and Validation Exercise #3.
NIST SP 1013-1; NIST Special Publication 1013-1; NUREG/CR-6905; 189 p. June 2005.
Hamins, A.; Maranghides, A.; Johnsson, E. L.; Donnelly, M. K.; Yang, J. C.; Mulholland, G. W.; Anleitner, R. L.
- Simulation of a Single Room Problem Using Code MAGIC. Appendix C.
NISTIR 6872; June 2002.International Collaborative Project to Evaluate Fire Models for Nuclear Power Plant Applications. Evaluation of Fire Models for Nuclear Power Plant Applications: Cable Tray Fires. International Panel Report. Appendix C: Benchmark Analysis With MAGIC, C/1-16 pp, 2002.
Gautier, B.; Ernandorena, H.; Kaercher, M.
- Study of Cable Tray Fires of Redundant Safety Trains With the Flamme[underscore]S Code. Appendix A.
NISTIR 6872; June 2002.International Collaborative Project to Evaluate Fire Models for Nuclear Power Plant Applications. Evaluation of Fire Models for Nuclear Power Plant Applications: Cable Tray Fires. International Panel Report. Appendix A: Benchmark Analysis With Flamme[underscore]S, A/1-39 pp, 2002.
Bouton, E.; Tourniaire, B.
Building and Fire Research Laboratory
National Institute of Standards and Technology
Gaithersburg, MD 20899